Testing of Plastic Combustion Performance

2019-06-21 11:14
Under fault or overload conditions, component systems or individual plastic parts may reach temperatures which causes them to deform, melt, or possibly ignite. Consideration must also be given to whether adjoining materials could aggravate these conditions or be ignited by a failing plastic material.
 
Underwriters Laboratories (UL94):
Underwriters Laboratories (UL) is an independent organization that provides product safety testing and certification. Their UL94 testing procedures and rating system for thermoplastics flammability are the generally accepted standard throughout most of the world.
 
Different UL94 ratings are given based on variations of the test method and results:
 
Horizontal Burn (HB Rating):
A specimen less than 3 mm thick is tested in a horizontal orientation. It must burn at a rate of less than 76 mm/min.
 
Vertical Burn (V-0 to V-2 Rating):
Specimen thickness is a element of this classification which is conducted in a vertical orientation. Burning must self extinguish within 10-30 seconds. The effect of dripped particles can also be monitored.
Material test results must be certified by UL in order to obtain a “yellow card” or Recognized Component status and bear their “UR” mark. Use of Recognized Component materials can be advantageous for obtaining a UL Listing for completed devices.
RTP Company has over 450 plastic compounds already Recognized by UL with a variety of flammability ratings. RTP Company also participates in UL’s Client Test Data Program which allows testing conducted by RTP Company to be accepted by UL, this procedure can expedite UL certification of new materials.
 
Glow Wire (IEC 60695-2-10):
Glow wire and needle flame test methods are popular in Europe for ascertaining the flammability of plastics.
These tests simulate thermal stresses to which materials may be subjected in a failure situation, such as the glowing elements of an overloaded resistor, to assess fire hazard.
 
Glow wire testing can be conducted using two methods:
Glow Wire Flammability Index:
Flame or glowing must self extinguish within 30 seconds after removal of the glow wire.
Glow Wire Ignition Temperature
No flame or glowing for more than 5 seconds while the glow wire is applied.
 
Other Testing Methods:
Numerous other flammability rating and testing methods exist that are specific to certain industries or applications. When requested, RTP Company can perform or obtain test results for candidate materials for these or other methods.
Automotive — FMVSS 302
Aerospace — FAR 25.853
Limiting Oxygen Index — ASTM D 2863 or ISO 4589
Flame spread — ASTM E 162
Smoke density — ASTM E 662
Heat release — ASTM E 1354

 

Related News

2023-10-26How do you measure oxygen levels in an experiment?
2023-10-26What is ASTM D6413?
2023-10-26What is ASTM D 695 standard test method for compressive properties of rigid plas
2023-10-26What types of construction materials are covered by ASTM standards?
2023-10-25Differences in the testing procedures between ASTM D2863 and ASTM D2863 17
2023-10-25What is the test method for limiting oxygen index?
2023-10-24What is 50% stretch in fabric?
2023-10-24How do you test fabric quality?
2023-10-24How are the materials are tested as per ASTM standards?
2023-10-24Can the oxygen index test be used to compare the fire resistance properties of d

Copyright 2022:Qinsun Instruments Co., Limited

High-end textile tester supplier  Email:info@qinsun-lab.com | Textile Testing Equipment pdf | Tel:021-67800179 |