Site: Home > Home > News and events
StandardNo. [Recommended standard added with T] | Description | Testing standards and equipment |
YY/T0969-2013 Disposable Medical Mask | Not applicable to medical protective masks and medical surgical masks |
Mask pull: strength machine Bacterial filtration efficiency BFE: bacterial filtration efficiency BFE tester Ventilation resistance: mask exchange pressure difference |
YY0469-2011 Medical Surgical Mask | Medical surgical mask |
Mask pull: strength machine Blood penetration: synthetic blood penetration tester Particulate matter filtration efficiency PFE: Automatic filter efficiency tester [Oiliness] corresponds to KP classification Automatic filtration efficiency tester [Salinity] corresponds to KN classification Bacterial filtration efficiency BFE: bacterial filtration efficiency BFE tester Mask exchange pressure difference: mask exchange pressure difference tester Flame retardant performance: flame retardant performance tester for masks |
GB 19083-2010 medical protective mask [mandatory standard] | medical respirators masks |
Mask pull: strength machine Blood penetration: synthetic blood penetration tester Particulate matter filtration efficiency PFE: Automatic filter efficiency tester [Oiliness] corresponds to KP classification Automatic filtration efficiency tester [Salinity] corresponds to KN classification Bacterial filtration efficiency BFE: bacterial filtration efficiency BFE tester Mask exchange pressure difference: mask exchange pressure difference tester Flame retardant performance: flame retardant performance tester for masks Tightness: mask tightness tester Airflow resistance: respirator breathing resistance tester Moisture resistance: mask adhesion tester |
GB 2626 -2006 respiratory protective articles self-priming filter respirator for preventing particulate matter | Not applicable to hazardous/anoxic/underwater/fire fighting, etc |
Mask pull: strength machine Particulate matter filtration efficiency PFE: Automatic filter efficiency tester [Oiliness] corresponds to KP classification Automatic filtration efficiency tester [Salinity] corresponds to KN classification Protective effect: mask protective effect tester Airflow resistance: respirator breathing resistance tester Flame retardant performance: flame retardant performance tester for masks Pretreatment: temperature and humidity pretreatment box/mechanical pretreatment box Leakage: mask leakage tester Airtightness: Airtightness tester for expiratory valve of mask Dead space: mask dead space tester Airtightness: Airtightness tester for mask |
GBT 32610-2016 technical specification for daily protective masks [recommended standard] | Not applicable to hazardous/anoxic/underwater/fire fighting/medical/industrial applications |
Mask pull: strength machine Particulate matter filtration efficiency PFE: Automatic filter efficiency tester [Oiliness] corresponds to KP classification Automatic filtration efficiency tester [Salinity] corresponds to KN classification Protective effect: mask protective effect tester Airflow resistance: respirator breathing resistance tester Colour fastness to rubbing: colour fastness to rubbing tester PH value: PH meter Formaldehyde: formaldehyde tester |