Site: Home > Home > Products > Property > Other

Filter Material Comprehensive Performance Test Bench

Description:The filter material comprehensive performance test bench is designed and manufacturing from experience the process of exploration and experiment, and with reference to YY0469-2004 "Technical requirements for surgical mask" and GB2626-2006 "Respiratory protective equipment - Non-powered air-purifying particle respirator" standard.

Factory Direct SalesQuality AssuranceLightning DeliveryHassle-free Service
Free Quote
Email
Filter Material Comprehensive Performance Test Bench

Product Details

Introduction
 · The filter material comprehensive performance test bench is designed and manufacturing from experience the process of exploration and experiment, and with reference to YY0469-2004 "Technical requirements for surgical mask" and GB2626-2006 "Respiratory protective equipment - Non-powered air-purifying particle respirator" standard. At the same time, it also refer to advanced design concepts of the international similar equipment, (such as the United States TSI company), which based on the "European standard EN1822-3: 1998 Testing flat sheet filter media" principle, but suitable for domestic related industry test status.
· It can be used with DEHS aerosol generator or NaCl aerosol generator or the atmosphere of a variety of filter, medical masks and a variety of protective equipment resistance, flow, efficiency and other performance determination. User-friendly design, with a simple operation, easy to use, for a wide range of features. It can instantly to provide complete data parameters to the sample.
 
Component
1) DEHS aerosol generator * 1 set
2) NaCl generator * 1 set
3) Laser dust particle counter * 2 sets (2.83 liters / min)
4) Micro differential pressure meter (import) * 1 (0-1000Pa digital display)
5) Flow meter * 2 (10-100 liters/ min)
6) High pressure fan * 1 set
7) Electrostatic neutralization device * 1 group
8) Dedicated spray pump * 1 set
9) Oil-free air compressor * 1 set (200 liters / min) (accessory)
10) Standard fixture * 1 pair (effective test area 100 cm2)
11) Control valve * 6 pcs
12) 50 cm2 (round) area plate * 1 pair (accessory)
13) Test software CD * 1 sheet (accessory)
14) Computer * 1 (accessory)
 
Technical Parameters
Items Parameters
 
Applicable filter
1) glass fiber filter material
2) PP filter material
3) film filter material
Detection of particle size 0.3, 0.5, 1.0, 2.0, 5.0, 10.0 μm (six level)
Flow range 20 ~ 100 L/ min
Detection resistance range 0 ~ 1000 Pa (standard)
 
Dust source
1) aerosol (DEHS)
2) sodium salt (2% NaCl solution)
3) Atmosphere
Effective test area 100 cm2
Electrostatic neutralization device heating power 300W / 220V
Power supply 220V/ 50 Hz 
System power consumption <1500W
Dimensions 910 mm (width) × 780 mm (depth) × 1400 mm (high)

Related Products

  • Tensile Strength Testing Equipment for Lea

    Tensile Strength Testing Equipment for Lea

    The filter material comprehensive performance test bench is designed and manufacturing from experience the process of exploration and experiment, and with reference to YY0469-2004 "Technical requirements for surgical mask" and GB2626-2006 "Respiratory protective equipment - Non-powered air-purifying particle respirator" standard.

  • Taber Leather Abrasion Resistance Tester

    Taber Leather Abrasion Resistance Tester

    The filter material comprehensive performance test bench is designed and manufacturing from experience the process of exploration and experiment, and with reference to YY0469-2004 "Technical requirements for surgical mask" and GB2626-2006 "Respiratory protective equipment - Non-powered air-purifying particle respirator" standard.

  • IEC60695 Glow Wire IEC Fire Hazard Testing

    IEC60695 Glow Wire IEC Fire Hazard Testing

    The filter material comprehensive performance test bench is designed and manufacturing from experience the process of exploration and experiment, and with reference to YY0469-2004 "Technical requirements for surgical mask" and GB2626-2006 "Respiratory protective equipment - Non-powered air-purifying particle respirator" standard.

  • ASTM D 2863, ISO 4589-2 Automatic Limited

    ASTM D 2863, ISO 4589-2 Automatic Limited

    The filter material comprehensive performance test bench is designed and manufacturing from experience the process of exploration and experiment, and with reference to YY0469-2004 "Technical requirements for surgical mask" and GB2626-2006 "Respiratory protective equipment - Non-powered air-purifying particle respirator" standard.

  • ISO105B02 Standard Textiles Xenon Aging La

    ISO105B02 Standard Textiles Xenon Aging La

    The filter material comprehensive performance test bench is designed and manufacturing from experience the process of exploration and experiment, and with reference to YY0469-2004 "Technical requirements for surgical mask" and GB2626-2006 "Respiratory protective equipment - Non-powered air-purifying particle respirator" standard.

  • Bag Zipper Reciprocation Pull Fatigue Test

    Bag Zipper Reciprocation Pull Fatigue Test

    The filter material comprehensive performance test bench is designed and manufacturing from experience the process of exploration and experiment, and with reference to YY0469-2004 "Technical requirements for surgical mask" and GB2626-2006 "Respiratory protective equipment - Non-powered air-purifying particle respirator" standard.

  • ISO 6925 Carpet Flammability Testing Equip

    ISO 6925 Carpet Flammability Testing Equip

    The filter material comprehensive performance test bench is designed and manufacturing from experience the process of exploration and experiment, and with reference to YY0469-2004 "Technical requirements for surgical mask" and GB2626-2006 "Respiratory protective equipment - Non-powered air-purifying particle respirator" standard.

  • Portable Mask Breathing Resistance Testing

    Portable Mask Breathing Resistance Testing

    The filter material comprehensive performance test bench is designed and manufacturing from experience the process of exploration and experiment, and with reference to YY0469-2004 "Technical requirements for surgical mask" and GB2626-2006 "Respiratory protective equipment - Non-powered air-purifying particle respirator" standard.

Leave Message

Send message or email info@qinsun-lab.com get favorable prices,reply tu you within 24 hours!

Copyright 2022:Qinsun Instruments Co., Limited

High-end textile tester supplier  Email:info@qinsun-lab.com | Textile Testing Equipment pdf | Tel:021-67800179 |