limiting oxygen index apparatus Introduction
 
To automatically determine the minimum quantity of oxygen required for combustion. The apparatus determines the flammability characteristics of the materials used in the production of electric cables. The oxygen percentage is detected by a paramagnetic transducer (O2 accuracy <0.1%), and the combustion occurs inside the glass column. The operator is fixing only the O2 ratio, while the N2 flux is kept constant by proportional valve of the electronic system. Two units separated, one to check the measurements and one to feed oxygen and nitrogen to the column where the testing sample is placed.

oxygen indexer testing machine Technical Parameters:

Oxygen concentration measurement range: 0-90%.
Oxygen concentration accuracy: ± 0.1%
Flow meter range: 1.0 ~ 10.0L / min
Oxygen concentration measurement accuracy: ± 0.4%.
Response time: <10s
Combustion cylinder air flow:40mm/s ± 2mm/s; concentration adjustment accuracy: ± 0.1%.
Top air flow of the combustion cylinder: 90mm±10mm/s。
Portable igniter, downward jet of 16±4mm, adjustable.
Measurement time up to 5mins, accuracy of ± 0.5S.
Dual flow meter and pressure gauge device: accuracy of ± 1%.
Test temperature range: 25 ℃ ~ 150 ℃。



oxygen index testing instrument Features:

Imported oxygen concentration sensor (paramagnetic oxygen concentration sensor for model F248A, electrochemical oxygen concentration sensor for model F248D ) showing the oxygen concentration accuracy of ± 0.1%.
High temperature resistant quartz glass tube, outlet diameter 40mm.
Supportive and non-supportive sample holder.
Portable ignition, easy to operate.
Patented gas flow control unit which equipped with mass flow controller mixing nitrogen and oxygen can precisely control the gas flow.
After setting the oxygen concentration on screen, PLC control system can automatically adjusts the oxygen concentration according to the set value , precise and easy control.
The gas mixing chamber with patented design can ensure that the oxygen concentration measurement more accurate and the mixture of oxygen and nitrogen more better.
LCD real-time can display flow, time , test data and other parameters.
Dual flow meter and pressure gauge device: accuracy of ± 1%.
Equipped with special ignition.

oxygen index tester manufacturers


Related Products

  • Tensile Strength Testing Equipment for Lea

    Tensile Strength Testing Equipment for Lea

    limiting oxygen index test equipment is used to determine the lowest oxygen density that tested materials keep steady burning under oxygen and nitrogen mixed gas.Buy oxygen index flammability tester at www.qinsun-lab.com

  • Taber Leather Abrasion Resistance Tester

    Taber Leather Abrasion Resistance Tester

    limiting oxygen index test equipment is used to determine the lowest oxygen density that tested materials keep steady burning under oxygen and nitrogen mixed gas.Buy oxygen index flammability tester at www.qinsun-lab.com

  • IEC60695 Glow Wire IEC Fire Hazard Testing

    IEC60695 Glow Wire IEC Fire Hazard Testing

    limiting oxygen index test equipment is used to determine the lowest oxygen density that tested materials keep steady burning under oxygen and nitrogen mixed gas.Buy oxygen index flammability tester at www.qinsun-lab.com

  • ASTM D 2863, ISO 4589-2 Automatic Limited

    ASTM D 2863, ISO 4589-2 Automatic Limited

    limiting oxygen index test equipment is used to determine the lowest oxygen density that tested materials keep steady burning under oxygen and nitrogen mixed gas.Buy oxygen index flammability tester at www.qinsun-lab.com

  • ISO105B02 Standard Textiles Xenon Aging La

    ISO105B02 Standard Textiles Xenon Aging La

    limiting oxygen index test equipment is used to determine the lowest oxygen density that tested materials keep steady burning under oxygen and nitrogen mixed gas.Buy oxygen index flammability tester at www.qinsun-lab.com

  • Bag Zipper Reciprocation Pull Fatigue Test

    Bag Zipper Reciprocation Pull Fatigue Test

    limiting oxygen index test equipment is used to determine the lowest oxygen density that tested materials keep steady burning under oxygen and nitrogen mixed gas.Buy oxygen index flammability tester at www.qinsun-lab.com

  • ISO 6925 Carpet Flammability Testing Equip

    ISO 6925 Carpet Flammability Testing Equip

    limiting oxygen index test equipment is used to determine the lowest oxygen density that tested materials keep steady burning under oxygen and nitrogen mixed gas.Buy oxygen index flammability tester at www.qinsun-lab.com

  • Portable Mask Breathing Resistance Testing

    Portable Mask Breathing Resistance Testing

    limiting oxygen index test equipment is used to determine the lowest oxygen density that tested materials keep steady burning under oxygen and nitrogen mixed gas.Buy oxygen index flammability tester at www.qinsun-lab.com

Leave Message

Send message or email info@qinsun-lab.com get favorable prices,reply tu you within 24 hours!

Copyright 2022:Qinsun Instruments Co., Limited

High-end textile tester supplier  Email:info@qinsun-lab.com | Textile Testing Equipment pdf | Tel:021-67800179 |