Site: Home > Home > Products > Property > Other

Leakage negative pressure tester for infusion device

Description:The leakage negative pressure tester is a special equipment designed according to the relevant provisions of the national standard (gb838-2005) designed to detect the sealing performance of the infusi

Factory Direct SalesQuality AssuranceLightning DeliveryHassle-free Service
Free Quote
Email
Leakage negative pressure tester for infusion device

Product Details

The leakage negative pressure tester is a special equipment designed according to the relevant provisions of the national standard (gb838-2005) designed to detect the sealing performance of the infusion device.

Technical Parameters:

1、environment:

operating temperature:5~40℃

relative humidity:(45~80)%

Power voltage:220V±22V

Grid frequency:50HZ±1HZ

2、 Specification:

Negative pressure test: -10 ~ -30kpa error is not greater than + 0.5KPa, LED digital display negative pressure.

Negative pressure output -10 ~ -30kpa + 0.5kpa, LED digital display negative pressure.

The negative pressure of the measuring system is maintained: within 1 minute, it shall not drift + 0.5kpa.

Duration of test: 60S, no more than 0.5KPa.

Partial list:

One mainframe;

One year warranty;

operating instructions;

The instrument is free to upgrade service according to national standard.

Usages

Infusion into not less than 25% of nominal capacity of the water, the tester is negative pressure on the output of the solid loading on the infusion pipe, the tester access network power supply, open the power switch, after waiting for negative pressure stable display of the digital meter, and then press the start button, the tester will automatically pumping air, the negative pressure expression to display Numbers - 20 KPa, automatic stop pumping air, timing starts at the same time, the 60 S, to maintain time during this period, after being stable pressure, no bubble phenomenon in the visual observation infusion (negative pressure display Numbers should be no more than the original value of 0.5 KPa).

Notes

Operators must be familiar with the use of the equipment.

The negative pressure on this test has been adjusted to -20 KPa to automatically stop pumping air.

Continuous time relay, the factory has been adjusted to 60 S.

This tester carries out three packs, three packs it is one year.

The measuring period of this tester is one year.

The setting method of time relay: set the dial to 3 bits, set the range of 1s-99s, and adjust the maintenance time according to the time setting.


Related Products

  • infusion apparatus Leakage positive pressu

    infusion apparatus Leakage positive pressu

    The leakage negative pressure tester is a special equipment designed according to the relevant provisions of the national standard (gb838-2005) designed to detect the sealing performance of the infusi

  • Leakage negative pressure tester for infus

    Leakage negative pressure tester for infus

    The leakage negative pressure tester is a special equipment designed according to the relevant provisions of the national standard (gb838-2005) designed to detect the sealing performance of the infusi

  • Ureter connector separation force tester

    Ureter connector separation force tester

    The leakage negative pressure tester is a special equipment designed according to the relevant provisions of the national standard (gb838-2005) designed to detect the sealing performance of the infusi

  • Syringe slide performance tester

    Syringe slide performance tester

    The leakage negative pressure tester is a special equipment designed according to the relevant provisions of the national standard (gb838-2005) designed to detect the sealing performance of the infusi

  • Medical needle toughness tester

    Medical needle toughness tester

    The leakage negative pressure tester is a special equipment designed according to the relevant provisions of the national standard (gb838-2005) designed to detect the sealing performance of the infusi

  • Anti Synthetic blood penetration tester

    Anti Synthetic blood penetration tester

    The leakage negative pressure tester is a special equipment designed according to the relevant provisions of the national standard (gb838-2005) designed to detect the sealing performance of the infusi

  • Friction Charging Tester

    Friction Charging Tester

    The leakage negative pressure tester is a special equipment designed according to the relevant provisions of the national standard (gb838-2005) designed to detect the sealing performance of the infusi

  • Static Honest Meter L1049

    Static Honest Meter L1049

    The leakage negative pressure tester is a special equipment designed according to the relevant provisions of the national standard (gb838-2005) designed to detect the sealing performance of the infusi

Leave Message

Send message or email info@qinsun-lab.com get favorable prices,reply tu you within 24 hours!

Copyright 2022:Qinsun Instruments Co., Limited

High-end textile tester supplier  Email:info@qinsun-lab.com | Textile Testing Equipment pdf | Tel:021-67800179 |